Iimveliso

  • I-ODOT-DPM01: I-Modbus-RTU kwi-Profibus-DP Converter

    I-ODOT-DPM01: I-Modbus-RTU kwi-Profibus-DP Converter

    ♦ Ixhasa ukuguqulwa kweprotocol phakathi kweModbus kunye nePROFIBUS

    ♦ Ixhasa i-RS485, i-RS422 kunye ne-Rs232

    ♦ Ixhasa i-Modbus master kunye nekhoboka, kwaye ixhasa i-RTU okanye i-ASCII

    ♦ Ixhasa indawo yokusebenza ye -40 ~ 85 °C

    ♦ PROFIBUS-DP: Max.Igalelo 244 bytes, Max.Imveliso 244 bytes

    ♦ DPM01:1-indlela ye-Modbus ukuya kwi-PROFIBUS isango lamakhoboka, isixa segalelo kunye nemveliso yi-288 bytes.

  • C3351 Modbus-TCP/Modbus-RTU PLC isilawuli (codesysv3.5)

    C3351 Modbus-TCP/Modbus-RTU PLC isilawuli (codesysv3.5)

    I-ODOT PLC C-3351 Codesys V3.5

    I-1.Inokuthenjwa, icwecwe, ilula ukwandisa i-IO, inokuxhasa ukuya kwiimodyuli ze-32 ze-I / O.

    2. Inokuthi isetyenziswe kumashishini amaninzi kunye neemeko ezifana nezixhobo zokulungisa oomatshini, ukucocwa kwamanzi amdaka, i-textile, i-automation engekho-standard, njl.

    3. Unxibelelwano olungenamthungo kunye noqhagamshelwano oluthembekileyo.Iseva ye-Modbus TCP kunye nomxhasi we-Modbus TCP zixhaswa ngaxeshanye.

    Ixhasa i-Modbus RTU inkosi okanye ikhoboka.

    4. Yinkqubo ecwangcisekileyo elandela umgangatho wezizwe ngezizwe we-IEC61131-3.Ixhasa iilwimi ezintlanu zokucwangcisa

    njengomzobo weleli (LD), uluhlu lwemiyalelo (IL), isicatshulwa esicwangcisiweyo (ST), umzobo webhloko yomsebenzi (CFC / FBD) kunye neTshati yokuSequential Function (SFC).

  • I-CT-2738 i-8 channels relay output 1A/30VDC/30W

    I-CT-2738 i-8 channels relay output 1A/30VDC/30W

    I-CT-2738 i-8 channels relay output 1A/30VDC/30W

    Iimpawu zemodyuli

    ◆ I-8-channel relay ngokuqhelekileyo kwimveliso

    ◆ Iimpawu ze-LED ze-8

    ◆ Ukuchasana okuphantsi (≤100mΩ)

    ◆ Ngokuzihlukanisa phakathi kwamajelo

    ◆ I-TVS eyakhelwe-ngaphakathi ye-bidirectional diode, isekethe ye-RC eyakhelweyo

    ◆ Imithwalo echasayo kunye ne-inductive inokudityaniswa

     

     

  • I-ODOT B32 / B64 series edibeneyo ye-I / O imodyuli-BOX-32 / 64

    I-ODOT B32 / B64 series edibeneyo ye-I / O imodyuli-BOX-32 / 64

    I-ODOT B imodyuli edibeneyo ye-I/O iquka ibhodi yonxibelelwano (ibhodi yeCOMM) imodyuli kunye nemodyuli ye-IO eyandisiweyo.Ibhodi ye-COMM inokukhetha imodyuli yebhasi ehambelanayo ngokubhekiselele kunxibelelwano lonxibelelwano lwenkqubo yokulawula.Iiprothokholi zonxibelelwano zezoshishino eziqhelekileyo ziquka i-Modbus, i-Profibus-DP, i-Profinet, i-EtherCAT, i-EtherNet / IP, i-CANopen, i-CC-Link, i-PowerLink, njl. Imodyuli ye-analog yegalelo, imodyuli yokuphuma kwe-analog, imodyuli ekhethekileyo, kunye nemodyuli ye-hybrid ye-I/O.

    Ibhodi ye-COMM kunye neemodyuli ze-IO ezandisiweyo zinokudibaniswa ngokukhululekileyo ngokusekelwe kwiimfuno zesayithi.Imodyuli ye-IO edibeneyo inokunciphisa iindleko xa kukho amanqaku ambalwa edatha.

  • I-ODOT ekude I/O Imodyuli

    I-ODOT ekude I/O Imodyuli

    Imodyuli yeprotocol eguquguqukayo kunye neplagi yemodyuli ye-I/O kunye nokudlala, iimpawu ezingezantsi:

    1. Eyilwe ngobuninzi beemodyuli ze-32, imodyuli nganye ye-I / O yakhiwe ngeeshaneli ze-16 kwaye nganye inesalathisi se-LED.

    2. Ixhasa amanqaku e-512 e-I/O kunye nokuziphilisa;

    3. I-module ye-I / O ye-back plate cable inokwandiswa ukuya kwiimitha ezili-15 ukuze isetyenziswe kwiipaneli ezininzi;

    4. I-WTP ivela -40 ~ 85℃ kunye newaranti yeminyaka emi-3;

    5. Isantya esiphezulu se-12M ibhasi ye-back plate, kunye ne-32 iimodyuli ze-digital quantity zexesha lokuhlaziya kwi-2ms kunye nobuninzi be-analog yi-2ms;

    6. Ixhasa i-Modbus-RTU, i-Modbus-TCP, i-Profinet, i-Profibus - DP (DPV0), i-EtherCAT, i-Ethernet / IP kunye nezinye ukuya kwii-12 iintlobo zeprotocol yomlambo oyintloko.

  • I-ODOT CN-8032: I-Adaptha yeNethiwekhi yeProfinethi

    I-ODOT CN-8032: I-Adaptha yeNethiwekhi yeProfinethi

    I-CN-8032 inethiwekhi ye-Profinet Iadaptha yebhasi

    I-1, Ixhasa umgangatho woNxibelelwano lweSixhobo seProfinet IO.

    2,Ixhasa i-MRP media redundancy, kwaye inokuqonda ukungafuneki kwenethiwekhi yeringi.

    I-3, Ixhasa i-RT / IRT yexesha langempela kunye nemo yonxibelelwano ehambelanayo, kunye ne-RT yonxibelelwano lwexesha langempela ubuncinane bexesha le-1ms kunye ne-IRT yonxibelelwano lwe-synchronous ubuncinane bexesha le-250us.

    I-4, Ixhasa igalelo elikhulu le-1440 bytes, ukukhutshwa okuphezulu kwe-1440 bytes, kunye ne-32pcs yeemodyuli ze-IO ezandisiweyo

  • I-ODOT CN-8033: I-EtherCAT Network Adapter

    I-ODOT CN-8033: I-EtherCAT Network Adapter

    Imodyuli ye-CN-8033 EtherCAT I / O ixhasa ukufikelela kweprotocol ye-EtherCAT eqhelekileyo.Iadaptha ixhasa iMax.igalelo le-1024 bytes kunye ne-Max.imveliso ye-1024 bytes.Ixhasa i-32 pcs yeemodyuli ze-IO ezandisiweyo.

  • Umlawuli we-EvoLink E547H PLC ene-IEC61499 esemgangathweni (Iza kungekudala)

    Umlawuli we-EvoLink E547H PLC ene-IEC61499 esemgangathweni (Iza kungekudala)

    Umlawuli we-EvoLink E547H PLC, Isizukulwana esitsha sePLC esekwe kwi-IEC61499.

    Iprothokholi yothungelwano : Modbus TCP, Modbus RTU,OPCUA,EtherNet/IP

    Isoftware yokucwangcisa : EAE kunye neODOT

    Imemori: 256M

    Imodyuli ye-IO exhaswayo: iipcs ezingama-64

     

  • I-ODOT CN-8034: I-EtherNET/IP Network Adapter

    I-ODOT CN-8034: I-EtherNET/IP Network Adapter

    I-ODOT CN-8034 EtherNET/IP i-Adapter yeNethiwekhi

    Imodyuli ye-CN-8034 Ethernet / IP I / O ixhasa ukufikelela kweprotocol ye-Ethernet / IP.Iadaptha ixhasa iMax.igalelo le-504 bytes kunye ne-Max.imveliso ye 504 bytes.Ixhasa i-32 pcs yeemodyuli ze-IO ezandisiweyo.

  • I-ODOT CN-8032-L:I-Adaptha yeNethiwekhi yeProfinet

    I-ODOT CN-8032-L:I-Adaptha yeNethiwekhi yeProfinet

    I-ODOT CN-8032-L I-Adaptha yeNethiwekhi yeNzuzo

    I-adapter yenethiwekhi ye-CN-8032-L yeProfinet ixhasa iNxibelelwano yeDivayisi yeProfinet IO eqhelekileyo.I-adaptha ixhasa ukungabikho kwe-MRP, kwaye akukho mfuneko yothungelwano lwendandatho.Kwaye ixhasa i-RT ye-real-time yonxibelelwano imodi, kunye ne-RT real-time yonxibelelwano ixesha elincinci le-1ms. I-adapter isekela igalelo elikhulu le-bytes ye-1440, imveliso ephezulu ye-1440 bytes, kunye nenani leemodyuli ze-IO ezandisiweyo ezixhasayo. 32.

    inkxaso akukho MRP redudancy, akukho msebenzi IRT

    Nceda ubukele ividiyo yethu yamva nje yeRemote IO kuyoutube: https://www.youtube.com/watch?v=O86lTEV8UdM&pp=sAQA

  • I-ODOT CN-8011: I-Adaptha yebhasi ye-Modbus-RTU

    I-ODOT CN-8011: I-Adaptha yebhasi ye-Modbus-RTU

    I-CN-8011 Modbus-RTU Bus Adapter

    Isishwankathelo semodyuli

    I-adaptha yenethiwekhi ye-CN-8011 Modbus-RTU ixhasa unxibelelwano oluqhelekileyo lwe-Modbus-RTU, ixhasa ikhowudi yokusebenza ye-01/02/03/04/05/06/15/16/23, kwaye esi sixhobo sinokubeka iliso kwimodyuli yonxibelelwano ye-IO ngokwenyani. ixesha.

  • I-CP-9131 umlawuli we-PLC

    I-CP-9131 umlawuli we-PLC

    I-CP-9131 yinguqulelo yokuqala ye-ODOT Automation PLC, indawo yokucwangcisa ilandela inkqubo ye-IEC61131-3 yamazwe ngamazwe enokucwangciswa, kwaye ixhasa iilwimi zeprogram ye-5 ezifana noLuhlu lweMiyalelo (IL), i-Ladder Diagram (LD), i-Structured Text (ST) , Umzobo weBloko yoMsebenzi (CFC / FBD) kunye neTshati yokuSebenza ngokulandelelana (SFC).

    I-PLC inokuxhasa ii-32 iipcs zeemodyuli ze-IO, kunye nokugcinwa kweprogram yayo isekela i-127Kbyte, ukugcinwa kwedatha isekela i-52Kbyte, indawo yokugcina idatha iqulethe indawo yokufaka i-1K (1024Byte), indawo yokuphuma kwe-1K (1024Byte), kunye nommandla ophakathi oguquguqukayo we-50K.

    Ngonxibelelwano oluqhelekileyo olwakhelwe ngaphakathi lwe-RS485 ujongano, ithwala kunye ne-2 RJ45 interfaces eyi-PLC encinci enemisebenzi ecebileyo.

    I-CP-9131 iyona nxalenye engundoqo yochungechunge lwe-C lonke, umsebenzi wayo oyintloko awuxanduva nje lokuqhuba inkqubo ye-logic yomsebenzisi, kodwa unoxanduva lwazo zonke iinkcukacha ze-I / O ezifumana kunye nokuthumela, ukusetyenzwa kwedatha yonxibelelwano kunye neminye imisebenzi.Ngemiyalelo etyebileyo, umsebenzi othembekileyo, ukulungelelaniswa kakuhle, ukwakheka kwe-compact, kulula ukwandisa, indleko-esebenzayo, ukuguquguquka okunamandla, ukuhlelwa kweprogram, ukubeka iliso, ukulungisa umonakalo, ukusebenza kwentsimi kulula kakhulu, i-PLC ingasetyenziselwa kwiinkqubo ezahlukeneyo zokuzenzekelayo.

    I-interface ye-Ethernet kwi-CPU isekela umsebenzi we-Modbus TCP Server, isekela uMthengi we-Modbus TCP ye-third party ukufikelela kwidatha, isekela umsebenzi we-Modbus TCP Client, isekela ukufikelela kwidatha ye-third party ye-Modbus TCP Server.

    Ichweba le-RS485 lixhasa inkosi ye-Modbus RTU, ikhoboka le-Modbus RTU, kwaye ixhasa izixhobo zomntu wesithathu ukunxibelelana ne-PLC nge-port ye-serial.