Uguqulelo lweProtocol

  • I-ODOT-DPM01: I-Modbus-RTU kwi-Profibus-DP Converter

    I-ODOT-DPM01: I-Modbus-RTU kwi-Profibus-DP Converter

    ♦ Ixhasa ukuguqulwa kweprotocol phakathi kweModbus kunye nePROFIBUS

    ♦ Ixhasa i-RS485, i-RS422 kunye ne-Rs232

    ♦ Ixhasa i-Modbus master kunye nekhoboka, kwaye ixhasa i-RTU okanye i-ASCII

    ♦ Ixhasa indawo yokusebenza ye -40 ~ 85 °C

    ♦ PROFIBUS-DP: Max.Igalelo 244 bytes, Max.Imveliso 244 bytes

    ♦ DPM01:1-indlela ye-Modbus ukuya kwi-PROFIBUS isango lamakhoboka, isixa segalelo kunye nemveliso yi-288 bytes.

  • I-ODOT-PNM02 V2.0 / V2.1: Modbus-RTU/ASCll okanye iprotocol engekho mgangathweni kwiProfiNet Converter

    I-ODOT-PNM02 V2.0 / V2.1: Modbus-RTU/ASCll okanye iprotocol engekho mgangathweni kwiProfiNet Converter

    I-ODOT-PNM02 V2.1

    I-Modbus (inkosi / ikhoboka, i-RTU / ASCII) ukuya kwi-ProfiNET, i-2 port serial port (RS485 / RS232 / RS422), ixhasa i-50 slots, imiyalelo ye-200 kwi-TIA

    portal (nge-software emiselweyo), inkxaso MAX 60 amakhoboka

    ♦ Ixhasa ukuguqulwa kweprotocol phakathi kweModbus kunye nePROFINET

    ♦ Ixhasa i-2 * RS485/RS232 okanye i-1 * RS422

    ♦ Ixhasa inkosi ye-Modbus okanye ikhoboka, kwaye ixhasa i-RTU okanye i-ASCII

    ♦ Ixhasa ubushushu bokusebenza be -40〜85°C

    ♦ Ixhasa indawo yedatha: i-2 ye-serial Modbus-RTU / ASCII ukuya kwi-PROFIBUS yesango nge-Max.igalelo 1440 bytesand Max.imveliso 1440 bytes

    ♦ Ixhasa ukusetwa kwakhona kweqhosha elinye

    ♦ I-ODOT-PNM02 V2.0 ixhasa iindawo eziphezulu zokubeka: 50

    ♦ I-ODOT-PNM02 V2.1 ixhasa amakhoboka angama-60 (i-200 yokufunda nokubhala imiyalelo)

  • I-ODOT-S4E2: 4 Uthotho lweModbus RTU/ASCII ukuya kwiModbus TCP converter

    I-ODOT-S4E2: 4 Uthotho lweModbus RTU/ASCII ukuya kwiModbus TCP converter

    ♦ Ixhasa ukuguqulwa kweprotocol phakathi kwe-Modbus-RTU kunye ne-Modbus-TCP

    ♦ Ixhasa uqhagamshelwano lwabaxumi be-TCP aba-5 ngaxeshanye

    ♦ I-ODOT-S2E2 ixhasa i-2 * RS485

    ♦ I-ODOT-S4E2 ixhasa i-wiring ye-RS485/RS232/RS422

    ♦ Izibuko ngalinye le-serial lixhasa i-Modbus master kunye nekhoboka

    ♦ I-ODOT-S2E2:2 i-serial Modbus-RTU/ASCII ukuya kwi-Modbus-TCP Server gateway

    ♦ I-ODOT-S4E2:4 i-serial Modbus-RTU/ASCII ukuya kwi-Modbus-TCP Server gateway

    ♦ Ixhasa ukusetwa kwakhona kweqhosha elinye

    ♦ Indlela yokusebenza yesango: Ugqithiso olucacileyo, idilesi yeemephu

  • I-ODOT-S2E2: 2 Uthotho lweModbus RTU/ASCII ukuya kwiModbus TCP Converter

    I-ODOT-S2E2: 2 Uthotho lweModbus RTU/ASCII ukuya kwiModbus TCP Converter

    ♦ Ixhasa ukuguqulwa kweprotocol phakathi kwe-Modbus-RTU kunye ne-Modbus-TCP

    ♦ Ixhasa uqhagamshelwano lwabaxumi be-TCP aba-5 ngaxeshanye

    ♦ I-ODOT-S2E2 ixhasa i-2 * RS485

    ♦ I-ODOT-S4E2 ixhasa i-wiring ye-RS485/RS232/RS422

    ♦ Izibuko ngalinye le-serial lixhasa i-Modbus master kunye nekhoboka

    ♦ I-ODOT-S2E2:2 i-serial Modbus-RTU/ASCII ukuya kwi-Modbus-TCP Server gateway

    ♦ I-ODOT-S4E2:4 i-serial Modbus-RTU/ASCII ukuya kwi-Modbus-TCP Server gateway

    ♦ Ixhasa ukusetwa kwakhona kweqhosha elinye

    ♦ Indlela yokusebenza yesango: Ugqithiso olucacileyo, idilesi yeemephu

  • MG-CANEX CANopen ukuba Modbus TCP converter

    MG-CANEX CANopen ukuba Modbus TCP converter

    MG-CANEX Protocol Converter

    CANopen kwiModbus TCP protocol converter

    I-MG-CANEX sisiguquli seprotocol ukusuka kwi-CANopen ukuya kwi-Modbus TCP.Esi sixhobo sidlala njengenkosi kuthungelwano lweCANopen kwaye sinokuqhagamshelwa kwizixhobo eziqhelekileyo zamakhoboka eCANopen.Ukuhanjiswa kwedatha kuxhasa i-PDO, i-SDO, kunye nolawulo lwempazamo luxhasa i-Heartbeat.Ixhasa ukuthumela imiyalezo ehambelanayo kunye ne-asynchronous.

    Njengomncedisi we-TCP kwinethiwekhi ye-Modbus TCP, isixhobo sinokufikelelwa ngabaxhasi be-5 TCP ngexesha elifanayo, kwaye sinokudibaniswa nomlawuli we-PLC kunye neentlobo ezahlukeneyo zesofthiwe yoqwalaselo.Inokudibanisa i-transceiver ebonakalayo kunye nokuqonda ukuhanjiswa kwedatha kumgama omde.

  • ODOT-S1E1 V2.0: Uthotho Gateway

    ODOT-S1E1 V2.0: Uthotho Gateway

    Lo ngumguquli ophuhliswe nguSichuan Odot Automation System Co., LTD phakathi kwe-RS232/485/422 kunye ne-TCP/UDP.Lo mguquli weprotocol unokudibanisa ngokulula izixhobo ze-serial port kwi-Ethernet kwaye uqaphele ukuphuculwa kwenethiwekhi yezixhobo ze-serial port.

    Umguquli weProtocol uxhasa umsebenzi "wokusasazwa kwedatha", enokuthi imiselwe njengomthengi okanye umncedisi.Lo msebenzi unokuqonda ngokulula unxibelelwano lwedatha phakathi kwe-PLC, iseva kunye nezinye izixhobo ze-Ethernet kunye nezixhobo ezisezantsi ze-serial port.

    Ixhasa iseva ye-TCP kunye ne-TCP client transparent transparent
    Ixhasa i-UDP transparent transparent and virtual serial port
    Ixhasa ukuhanjiswa okuselubala kunye okanye ngaphandle kweprotocol.Ugqithiso oluselubala lweProtocol luxhasa iMODBUS RTU/ASCII
    Ixhasa uqwalaselo umkhangeli wewebhu parameters (Iiparamitha eziqhelekileyo) Uthotho port baud rate 1200 ukuya 115200 bps

  • I-ODOT-S7MPIV2.0: PPI/MPI/PROFIBUS Ujongano kwi-EtherNet

    I-ODOT-S7MPIV2.0: PPI/MPI/PROFIBUS Ujongano kwi-EtherNet

    ♦ Ifakwe kwi-PPI/MPI/PROFIBUS kwizibuko lonxibelelwano lwePLC, ngokubanzi ngaphandle konikezelo lwamandla lwangaphandle

    ♦ Inkxaso ye-Siemens S7 Ethernet abaqhubi bonxibelelwano, kuquka iMicroWIN, STEP7, TIA Portal, WinCC njl.

    ♦ Idityaniswe kunye neseva ye-Modbus-TCP, indawo yedatha ye-Modbus inokuzenzekela okanye ihlelwe kwimephu ukubhalisa i-S7-200/300/400

    ♦ Uqhagamshelwano lwe-S7TCP kunye nonxibelelwano lwe-Modbus-TCP lunokwenziwa ngaxeshanye

    ♦ Ukuya kuthi ga kwi-32 inginginya uqhagamshelo lwekhompyutha oluxhaswayo

    ♦ IMPI ukuya kwi-S7 Ethernet/Modbus-TCP converter

    ♦ Ixhasa ukusetwa kweSitshixo esinye